L'acciaio nel restauro del Convento di S. Agostino a Corleone (PA)

2007

The paper describes the techniques adopted for the static and seismic retrofitting of the S. Agostino Convent in Corleone (PA), which is classified as II category seismic zone in the Italian Code. In this work many maintenances have been conducted with the use of inox steel and carbon steel. The main works consist in new decks, built with steel - concrete system, a new stair, two elevators and interventions in the masonry active ties with the use of stainless steel ribbons. This last method is named C.A.M.. A lot of details of the verification criteria and of the constructive solutions are showed.

isolamento sismico pendolo ad attrito dissipazione
researchProduct

Isolamento sismico di serbatoi di impianti chimici a Priolo Gargallo (SR)

2013

I serbatoi di stoccaggio degli impianti petrolchimici costituiscono una seria minaccia alla salvaguardia dell’ambiente, a causa delle conseguenze disastrose derivanti da un loro collasso, come messo in luce dai recenti eventi catastrofici. Pertanto, l’ENEA ed il GLIS hanno intrapreso un’intensa attività di ricerca e di informazione per sensibilizzare l’opinione pubblica su tali importanti pericoli. Tra le cause più frequenti di collasso si citano le azioni sismiche, particolarmente rilevanti in zone prossime a faglie attive, come risulta quella di Priolo Gargallo, in provincia di Siracusa, già sede di sismi distruttivi. I danni sono stati spesso ingigantiti dagli incendi sviluppatisi in seg…

Isolamento sismico pendolo ad attritoSettore ICAR/09 - Tecnica Delle Costruzioni
researchProduct

Risposta sismica di edifici prefabbricati isolati con dispositivi elastomerici

2013

The paper concerns the seismic behavior of precast concrete industrial buildings with an elevation equipped with seismic isolators. It’s examined a building with rectangular plan of m 40x 50. The structure is constituted of columns of square cross-section of 0.6 m, with continuum beams foundation. The desk is made with T section beams for each frame connected by Gerber joints in the main direction and they support precast pre-tensioned tiles with  shape. A plate of concrete is casted of the wing tiles for obtain a connected rigid deck. At the top of the pillars will be placed rubber bearings having high dissipation capacity (HDRB). The dynamic behavior of the structure under recorded real …

Settore ICAR/09 - Tecnica Delle CostruzioniIsolamento sismico strutture prefabbricate in cemento armato isolatori sismici ad alta dissipazione.
researchProduct